Issues Corrected in this Version
Problem
ID
Symptom
4321 The uninstall script is located in the UninstallerData subdirectory instead of the main
installation directory.
4324 If installing on a UNIX platform as root, you cannot install in the home directory.
4392 After the installation is complete, the installer may tell the user to click “Done” to quit
the installer when the user really must click “Next” and then “Done”.
4466 On the "Install Complete" screen, if the user selects the "Previous" button, all other
buttons become inactive and the user is forced to make an un-graceful exit. Note that at
this point, the GUI has already been installed.
4467
When exiting the Installer, an "Install Not Complete" message is received that states
["...To cancel Install select "Quit"" and "...If you exit, the SANbox Manager will not be
installed."]
The installation is not cancelled and the SANbox Manager remains installed even if the
"Quit" button is selected.
4328 If you make a change, for example changing port state, that change may not be
instantaneous and no wait message or other indication is given.
4417 The “Load Firmware” and “Edit Zoning” dialog boxes can become hidden behind the
main window and give the appearance that the GUI is hung.
4562 The port loopback test times out occasionally on a multi-processor system.
4692 When changing DomainID to a value greater than 31, a warning message is presented
telling you that the DomainID is invalid but the operation is allowed.
4763 On Windows based PCs, on occasion the GUI will abort when entering the faceplate
display. Restarting the GUI will correct this problem. This bug is caused by Sun Bug
IDs: 4482430, 4500800 and 4523926.
4764 If an ISL goes down between a SANbox2 and McData switch, the ISL state is
sometimes not reflected until you click on Refresh.
4765 If “set switch state” is used in CLIsh to set the switch offline, the GUI does not
recognize this state. This is because “set switch state” in CLIsh is a temporary setting.
The GUI reflects the permanent setting set by “set config switch”.
4774 With a mixed SANbox 1Gb and SANbox2 switch configuration, if you add a fabric to
SANbox Manager by entering the IP address of a SANbox 1Gb switch, there are
intermittent performance problems. This is noticed by occasional short delays in
processing requests and/or the switches not responding (blue status icons) for a few
seconds.
4791 When running offline/online tests on E_Ports, the GUI will occasionally show a port as
offline when it is actually online and operational. A workaround is to do a fabric
refresh. The correct port states will then show up.
4818 The GUI may lock up during fabric rediscovery after doing zone deletion, creation, and
merging. The GUI will repaint the screen and return to normal operation, but this may
take several minutes.