Qlogic OFED+ Host Specifikace Strana 65

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 204
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 64
4–InfiniPath Cluster Setup and Administration
Checking Cluster and Software Status
IB6054601-00 H 4-29
A
Checking Cluster and Software Status
ipath_control
InfiniBand status, link speed, and PCIe bus width can be checked by running the
program ipath_control. Sample usage and output are as follows:
$ ipath_control -iv
$Id: QLogic OFED Release 1.4 $ $Date: 2009-03-10-10:15 $
0: Version: ChipABI 2.0, InfiniPath_QLE7280, InfiniPath1 5.2,
PCI 2, SW Compat 2
0: Status: 0xe1 Initted Present IB_link_up IB_configured
0: LID=0x1f MLID=0xc042 GUID=00:11:75:00:00:ff:89:a6 Serial:
AIB0810A30297
0: HRTBT:Auto RX_polarity_invert:Auto RX_lane_reversal: Auto
0: LinkWidth:4X of 1X|4X Speed:DDR of SDR|DDR
0: LocalBus: PCIe,2500MHz,x16
ibstatus
Another useful program is ibstatus. Sample usage and output are as follows:
$ ibstatus
Infiniband device ’ipath0’ port 1 status:
default gid: fe80:0000:0000:0000:0011:7500:00ff:89a6
base lid: 0x1f
sm lid: 0x1
state: 4: ACTIVE
phys state: 5: LinkUp
rate: 20 Gb/sec (4X DDR)